Experimental
Rig
Current Research
Previous Publications
Liquid-Phase
Sintering
Routing Page
NASA
LeRC Microgravity
Science Division
Related Websites |
| IML-2
Compositions |
98W (7Ni:3Fe)
93W (7Ni:3Fe)
93W LPS (7Ni:3Fe)
93W Green (7Ni:3Fe)
88W (7Ni:3Fe)
83W (7Ni:3Fe)
78W (7Ni:3Fe)
PS: H2 presintered at 1400°C, 1h
LPS: H2 presintered at 1500°C, 1min
Green: Compacted at 210 MPa
Tungsten content in weight percent (that is 93W represents 93 wt.% W with
7 wt% Ni-3Fe).
In addition, notation is for powder blends, since liquid will retain W after
processing lowering the W content.
Experimental Conditions
Six cartridges containing 7 samples (one for each composition) were sintered
at 1500°C for 1, 60, and 120 minutes under microgravity and 1 g conditions.
Raw Data of IML-2, click here. |
|
| MSL-1
Compositions |
| W-Ni-Fe |
W-Ni-Cu |
93W Green (7Ni:3Fe)
78W PS (7Ni:3Fe)
78W Green (7Ni:3Fe)
78W LPS (7Ni:3Fe)
78W HIP (7Ni:3Fe)
78W Ar PS (7Ni:3Fe)
78W vacuum PS (7Ni:3Fe)
65W PS (7Ni:3Fe)
50W PS (7Ni:3Fe)
35W PS (7Ni:3Fe) Green:
compacted 200 MPa
PS: H2 presintered at 1400°C, 1
h
LPS: H2 presintered at 1500°C,
1min
HIP: presintered at 1000°C, 100 MPa, 1 h
Ar PS: Ar presintered at 1400°C, 1 h
Vacuum PS: presintered at 1400°C, 1h under
vacuum (10-4 torr) |
88W
(8Ni:2Cu)
50W (8Ni:2Cu)
88W (6Ni:4Cu)
50W (6Ni:4Cu) PS:
H2 presintered at 1000°C, 1 h |
Tungsten content in weight percent (that
is 93W represents 93 wt.% W with 7 wt% Ni-3Fe).
In addition, notation is for powder blends, since liquid will retain
W after processing lowering the W content.
Experimental Conditions
10 cartridges containing 7 samples sintered at 1500°C for 1,
45, 120, 180, and 600 minutes under microgravity and 1-g conditions.
|
|